Case studies
Gallions Ecopark, Thamesmead -Detailed Information
- New build housing: 39 houses, 8 flats
- Environmentally sustainable design
- Dutch Green Financing Model
- Post-completion monitoring
- Replicable
- Tried & trusted: not intended to be cutting edge!
Project Features
- Extra insulation
- Swedish windows
- Argon gas filled double glazing, achieves U= 1.1w/m2k
- Sunspaces
- Solar collectors
- Non UPVC use (i.e. gutters, flooring)
- Low VOC paints
- Waste segregation (inside & outside)
- Walls
- Double insulation, U =0.25 w/m2k
- Timber frame construction
Heating:
- Aquasol solar collector panels for preheating domestic water
- Gas condensing boilers, 83-98% efficient
- Radiators
- 60/40 short DHW piping
- low temperature heating
- very small radiators
- Underfloor heating in some units
Ventilation:
- Wind pressure vents
- Some mechanical ventilation with low energy fans
Sun space:
- 2 storey attic area exposed
- east/west orientation to heat incoming air
Water:
- dual flush toilets 2.5 /4 litres
- water saving spray taps
- flow regulators
- 1500mm baths
- rainwater collection for garden use